[跳至主要內容](#main-content)

# 疑難排解 WMI 查詢問題

如果效能計數器已損毀，則您會在 Resource Monitoring Tool 代理程式中看到問題。此問題將會在背景程式記錄檔中報告，並看起來類似下列範例：

```
{  ...  
"Level":  "Error",  ...  
"RenderedMessage":  "Error getting network adapters",  
"Exception":  "System.Management.ManagementException: * Invalid query  *  
       at System.Management.ManagementException.ThrowWithExtendedInfo(ManagementStatus errorCode) ..."  
...  }
```

這可能是由伺服器上有些效能計數器遺失造成的。若要檢查此問題，請執行 `perfmon.exe` 並檢查是否有任何警告訊息。

如果 `perfmon.exe` 確認效能計數器遺失，您可以重建所有計數器以嘗試修復。請參閱下文。

**重建所有效能計數器：**

若要重建所有效能計數器，請在系統管理命令提示字元中鍵入下列命令。在鍵入每個命令之後按 ENTER。

```
cd c:\windows\system32
lodctr /R
cd c:\windows\sysWOW64
lodctr /R
```

接下來，使用 Windows Management Instrumentation (WMI) 重新同步計數器：

```
WINMGMT.EXE /RESYNCPERF
```

最後，停止並重新啟動效能記錄及警示服務。