# STC Protector

> For the full documentation index, see: https://docs.mulesoft.com/llms.txt

When creating a _Workflow_ that needs to run stably and robustly for long periods, pop-up windows
can be difficult to handle. Mostly they appear irregularly, so it is not easy to implement them into
a static _Workflow_.

To handle these pop-ups, you can use _STC Protector_. Think of it as a process running parallel to
your actual measurement _Workflow_, checking if any window appears onscreen, and then closing it in
an instant by sending a predefined keystroke sequence.

## Properties

- **Pause between keystrokes, ms** Define how long _the Robot_ should pause between each keystroke
  sequence

- **Use regular expression for window title** You can further distinguish between window titles by
  selecting this checkbox. For a short introduction to regular expressions, see
  [Using Regular Expressions](https://docs.mulesoft.com/rpa-builder/latest/advanced-concepts-using-regular-expressions).

- **Use window text** Defines if, in addition to the window title, window text should also be used
  to identify the window that the keystrokes should be sent to

- **Window check type** Sets whether the protector reacts if a window merely exists or if it has to
  be active to be handled by _STC Protector._

## Wizard

Click _Start_ to begin recording the keystroke sequence for handling pop-up windows. Select the
pop-up window with the mouse and press the combination of keys needed to close it. When you are
finished, click _Stop_. A new line for this window will appear in the _STC Protector_ wizard.

The pop-up windows are identified by the window title. Make sure only one line exists for each
window title!

You can also add pop-up windows that are not actually onscreen. Use the **+** button and enter the
window title and the combination of keys needed to close it.

Some applications open pop-up windows that have the exact same title as the main application. In
this case, the _STC Protector_ cannot decide which window should be handled by means of the title
alone. To avoid this problem activate _Use window text_ before clicking _Start_. Now _STC Protector_
will use text displayed in the window and not only its title to decide whether it is a pop-up window
to be closed.

You can also distinguish between window titles by using the checkbox _Use regular expression for
window title_. This function is described in detail in Section
[Using Regular Expressions](https://docs.mulesoft.com/rpa-builder/latest/advanced-concepts-using-regular-expressions).

## Example

When there is more than one tab opened in _Internet Explorer_, the program asks you if they should
all be closed when you wish to exit the application. This question is displayed in a pop-up window.

Now, during execution, when the pop-up window appears, the _STC Protector_ will automatically send
the **_Enter_** keystroke to it and thus close the window.

To ensure that the window is closed as quickly as possible (to avoid any interference with the
measurement), leave the _Pause between keystrokes_ setting at "0".

## Troubleshooting

In extremely rare cases, the _Workflow_ seems to stop and do nothing more after a pop-up window has
been handled. This might be the case when the window is not actually closed by the given keystroke
sequence, but the main application hides it completely from the desktop without removing the window
handle from the operating system. In such cases, try setting _Window Check type_ to _Active_.