# Configure Alerts for Anypoint Platform PCE

> For the full documentation index, see: https://docs.mulesoft.com/llms.txt

Anypoint Platform Private Cloud Edition (Anypoint Platform PCE) provides built-in alerts that are
triggered when a condition specified in any alert definition is detected.

Measurements are stored in [Prometheus](https://prometheus.io/docs/introduction/overview/) and read
by [Alertmanager](https://prometheus.io/docs/alerting/latest/alertmanager/). Alertmanager sends
emails when an alert is triggered.

## Alert Definitions

Default alerts are listed in the following table:

<table><caption>Table 1. Alert Definitions</caption> <colgroup><col> <col> <col></colgroup><thead><tr><th>Component</th><th>Alert</th><th>Description</th></tr></thead><tbody><tr><td><p>CPU</p></td><td><p>High CPU usage</p></td><td><p>Triggers a warning when &gt; 75% used; triggers a critical error when &gt; 90% used</p></td></tr><tr><td><p>Memory</p></td><td><p>High memory usage</p></td><td><p>Triggers a warning when &gt; 80% used; triggers a critical error when &gt; 90% used</p></td></tr><tr><td><p>Systemd</p></td><td><p>Overall systemd health</p></td><td><p>Triggers an error when systemd detects a failed service</p></td></tr><tr><td><p>Systemd</p></td><td><p>Individual systemd unit health</p></td><td><p>Triggers an error when a systemd unit is not loaded or active</p></td></tr><tr><td><p>Filesystem</p></td><td><p>High disk space usage</p></td><td><p>Triggers a warning when &gt; 80% used; triggers a critical error when &gt; 90% used</p></td></tr><tr><td><p>Filesystem</p></td><td><p>High inode usage</p></td><td><p>Triggers a warning when &gt; 90% used; triggers a critical error when &gt; 95% used</p></td></tr><tr><td><p>System</p></td><td><p>Uptime</p></td><td><p>Triggers a warning when the uptime for a node is less than five minutes</p></td></tr><tr><td><p>System</p></td><td><p>Kernel parameters</p></td><td><p>Triggers an error if a parameter is not set. See <a href="https://github.com/gravitational/gravity/blob/master/docs/8.x/requirements.md#kernel-module-matrix" target="_blank" rel="noopener">value matrix</a> for details.</p></td></tr><tr><td><p>Etcd</p></td><td><p>Etcd instance health</p></td><td><p>Triggers an error when an etcd leader is down longer than five minutes</p></td></tr><tr><td><p>Etcd</p></td><td><p>Etcd latency check</p></td><td><p>Triggers a warning when follower &lt;→ leader latency exceeds 500 ms; triggers an error when it exceeds one second over a period of one minute</p></td></tr><tr><td><p>Docker</p></td><td><p>Docker daemon health</p></td><td><p>Triggers an error when the Docker daemon is down</p></td></tr><tr><td><p>Kubernetes</p></td><td><p>Kubernetes node readiness</p></td><td><p>Triggers an error when the node is not ready</p></td></tr></tbody></table>

## Configure Alert Definitions

You define new alerts using a gravity resource called `alert`, as shown in the following example:

```copy
kind: alert
version: v2
metadata:
name: cpu-alert
spec:
# the alert name
alert_name: CPUAlert
# the rule group the alert belongs to
group_name: test-group
# the alert expression
formula: |
    node:cluster_cpu_utilization:ratio * 100 > 80
# the alert labels
labels:
    severity: info
# the alert annotations
annotations:
    description: |
    Cluster CPU usage exceeds 80%.
```

See the [Alerting Rules](https://prometheus.io/docs/prometheus/latest/configuration/alerting_rules/)
documentation for more details about Prometheus alerts.

- To create an alert, run:

  gravity resource create alert.yaml

- To view existing alerts, run:

  gravity resource get alerts

- To remove an alert, run:

  gravity resource rm alert cpu-alert

## Configure Alerts Delivery

To configure Alertmanager to send email alerts, create the following gravity resources:

1.  Using the following spec, create a file named `smtp-config.yaml` inside gravity, and replace the
    placeholder values with those of your SMTP configuration:

    ```copy
    kind: smtp
    version: v2
    metadata:
        name: smtp
    spec:
       host: <SMTP_HOST>
       port: <SMTP_PORT>
       username: <SMTP_USERNAME>
       password: <SMTP_PASSWORD>
    ---
    kind: alerttarget
    version: v2
    metadata:
        name: email-alerts
    spec:
        # email address of the alerts recipient
        email: <RECIPIENT_EMAIL>
    ```

2.  Run `gravity resource create smtp-config.yaml`. You should see the following output:

    Created cluster SMTP configuration Created monitoring alert target "email-alerts"

3.  Add a default router to the Alertmanager configuration inside gravity:

    kubectl get secret -n monitoring alertmanager-monitoring-kube-prometheus-alertmanager -o json |
    jq --arg foo
    "$(kubectl get secret -n monitoring alertmanager-monitoring-kube-prometheus-alertmanager -o json | jq -r '.data\["alertmanager.yaml"\]' | base64 -d | yq r - --tojson | jq -r '.route.routes\[1\] |= . + {"match":{"alertname": "Watchdog", "receiver": "default", "continue": true}}' | jq -r '.route.routes\[0\].match += {"continue":true}' | yq r - -P | base64 | tr -d '\\n')" '.data\["alertmanager.yaml"\]=$foo'
    | kubectl apply -f -

4.  Configure the FROM email address by replacing the <SMTP\_FROM> value:

    kubectl get secret -n monitoring alertmanager-monitoring-kube-prometheus-alertmanager -o json |
    jq --arg foo
    "$(kubectl get secret -n monitoring alertmanager-monitoring-kube-prometheus-alertmanager -o json | jq -r '.data\["alertmanager.yaml"\]' | base64 -d | yq w - 'global.smtp\_from' <SMTP\_FROM> | base64 | tr -d '\\n')" '.data\["alertmanager.yaml"\]=$foo'
    | kubectl apply -f -

5.  Restart Alertmanager pods:

    kubectl delete pod -n monitoring -l app=alertmanager

6.  Test Alertmanager by running the following command inside gravity:

    curl -H 'Content-Type: application/json' -d
    '\[{"labels":{"alertname":"test-alert","state":"firing"}}\]'
    http://monitoring-kube-prometheus-alertmanager.monitoring.svc.cluster.local:9093/api/v1/alerts

## Troubleshooting Alerts

Common troubleshooting tasks include the following:

- Verify that your SMTP server can send and receive emails using the addresses you defined as the
  `FROM` and `TO` addresses when you configured alerts delivery.

- Verify that your cluster nodes can communicate with your SMTP server.

  For example, use `telnet` to connect to your SMTP server from one of your cluster nodes:

  telnet my.smtp.server.com 587 Trying XXX.XXX.XXX.XXX... Connected to my.smtp.server.com. Escape
  character is '^\]'. 220 my.smtp.server.com ESMTP ^\[^\] telnet> quit Connection closed.

## See Also