---
schema_version: "1"
id: 789e825521756f904c0634a69f0c6fc9c4b796fb51058b2e3e6e4b5e79a3e372
title: Configure Circuit Breaker for Managed Omni Gateway
collection: mulesoft
version: current
locale: en-us
portal_url: https://docs.salesforce.com/mulesoft/current/en-us/gateway/1.13/managed-circuit-breaker.md
canonical_url: https://docs.mulesoft.com/gateway/1.13/managed-circuit-breaker
source_site: docs.mulesoft.com
content_type: documentation
content_hash: aab25d10a1e8485e73b0ae19bd2ae1022bcb200224e962ae4229e4c34f9180f7
description: MuleSoft Documentation Site
release: "1.13"
latest: false
---
---
product: Omni Gateway
version: 1.13
---

# Configure Circuit Breaker for Managed Omni Gateway

> For the full documentation index, see: https://docs.mulesoft.com/llms.txt

Omni Gateway offers these circuit breaker thresholds:

- **Maximum Connections**  
  The maximum number of connections per API to an upstream service.

- **Maximum Pending Requests**  
  The maximum number of queued requests that can wait for a connection.

- **Maximum Requests**  
  The maximum number of outstanding requests to an upstream service.

- **Maximum Retries**  
  The maximum number of outstanding retries.

- **Maximum Connection Pools**  
  The maximum number of connection pools concurrently initiated to an upstream service.

> [!NOTE] When requests or connections exceed a threshold, Omni Gateway returns a
> `503 - Service Unavailable` error.

All thresholds are optional. For Managed Omni Gateways and Connected Mode, each API instance has its
own independent limit per upstream, so each can use the full threshold value. In Local Mode,
different API instances share limits for the same upstream. For all modes, each gateway replica can
use the full threshold value and limits aren’t distributed across replicas.

Configure circuit breaker thresholds for Managed Omni Gateway via:

- Runtime Manager runtime configurations: Applies to all API instances in the gateway after the
  gateway is deployed.

- Policy: Applies to one API instance or upstream and provides granular control.

## Configure Circuit Breaker in Runtime Manager

1.  In Anypoint Platform, select **Runtime Manager**.

2.  Select **Omni Gateways**.

3.  Select your Omni Gateway.

4.  Open **Runtime Configurations**.

5.  Open **Circuit Breaker**.

6.  Set values for **Maximum Connections**, **Maximum Pending Requests**, **Maximum Requests**,
    **Maximum Retries**, and **Maximum Connection Pools**.

7.  Apply the changes.

## Configure Circuit Breaker via Policies

Apply the Circuit Breaker policy to your API instance or upstream service:

- [Circuit Breaker Policy](https://docs.mulesoft.com/gateway/1.13/policies-outbound-circuit-breaker)
