schema_version: "1"
id: 4c3117bb39cdac0af658a557cf0dc727a897b08801d2d8ff03b83e86c383c329
title: Device
collection: legacydeveloper
version: current
locale: en-us
portal_url: https://docs.salesforce.com/legacydeveloper/current/en-us/health_cloud_object_reference/map_fhir_device.md
canonical_url: https://developer.salesforce.com/docs/atlas.en-us.health_cloud_object_reference.meta/health_cloud_object_reference/map_fhir_device.htm
source_site: developer.salesforce.com
content_type: documentation
content_hash: 624e4dccb33f7c3e59813a87c08c6f0822cbd9e80e2ff76e127002d5b159d894
description: The Device F​HI​R resource maps to the Asset and ​​Care​Registered​Device​ objects in Salesforce​.
---
# Device

The Device F​HI​R resource maps to the Asset and ​​Care​Registered​Device​ objects in Salesforce​.

## F​HI​R V4​.0 - ​Clinical ​Data ​Model ​Mapping

​Here’s how the fields defined by F​HI​R for [Device](https://www.hl7.org/fhir/device.html) map to the fields in Salesforce​.

Table 1. ​Patient - Salesforce
| Device ​Resource | Salesforce Field | ​Type | Salesforce ​Cardinality | Notes |
| --- | --- | --- | --- | --- |
| identifier | ​​​Identifier | Object | 0​.​M | The identifier information for a device is represented as Identifier records that reference the CareRegisteredDevice record using their ​​​Identifier​.​Parent​RecordId field​. |
| uidCarrier​.Device​Identifier | ​​Care​Registered​Device​​.Unique​Device​Id1 | External Lookup | 0.3 | While FHIR defines uidCarrier​.Device​Identifier as a zero-to-many value, the Salesforce implementation supports a maximum of three values using three fields. |
| uidCarrier​.Device​Identifier | ​​Care​Registered​Device​​.Unique​Device​Id2 | External Lookup | 0.3 | While FHIR defines uidCarrier​.Device​Identifier as a zero-to-many value, the Salesforce implementation supports a maximum of three values using three fields. |
| uidCarrier​.Device​Identifier | ​​Care​Registered​Device​​.Unique​Device​Id3 | External Lookup | 0.3 | While FHIR defines uidCarrier​.Device​Identifier as a zero-to-many value, the Salesforce implementation supports a maximum of three values using three fields. |
| uidCarrier​.Issuer | ​​Care​Registered​Device​​.Unique​Device​Id1​Issuer | URL | 0.3 | While FHIR defines uidCarrier​.Issuer as a zero-to-many value, the Salesforce implementation supports a maximum of three values using three fields. |
| uidCarrier​.Issuer | ​​Care​Registered​Device​​.Unique​Device​Id2​Issuer | URL | 0.3 | While FHIR defines uidCarrier​.Issuer as a zero-to-many value, the Salesforce implementation supports a maximum of three values using three fields. |
| uidCarrier​.Issuer | ​​Care​Registered​Device​​.Unique​Device​Id3​Issuer | URL | 0.3 | While FHIR defines uidCarrier​.Issuer as a zero-to-many value, the Salesforce implementation supports a maximum of three values using three fields. |
| uidCarrier​.jurisdiction | N/​A | N/​A | N/​A | Not supported |
| uidCarrier​.carrierAIDC | N/​A | N/​A | N/​A | Not supported |
| uidCarrier​.arrierHRF | N/​A | N/​A | N/​A | Not supported |
| uidCarrier​.entryType | N/​A | N/​A | N/​A | Not supported |
| status | ​​Asset.​Status | Picklist | 0​.1 | While F​HI​R defines device.status​ as code, the Salesforce implementation is a picklist​. |
| status​Reason | ​​Asset.​Status​Reason | Picklist | 0.1 | While F​HI​R defines device.status​Reason as a zero-to-many codeable concept, the Salesforce implementation is a zero-to-one picklist​. |
| distinct​Identifier | ​​Asset.​Uuid | String | 0.1 | N/A |
| manufacturer | ​​Asset.​Asset​Provider​By | Lookup: Account | 0.1 | While F​HI​R defines device.manufacturer​ as string, the Salesforce implementation is a lookup to Account (Organization)​. |
| manufacture​Date | ​​Asset.​Manufacture​Date | Date | 0.1 | While F​HI​R defines device.manufactureDate as DateTime, the Salesforce implementation is a of the data type Date. |
| expiration​Date | ​​Asset.​Usage​End​Date | Date | 0​.1 | While F​HI​R defines device.expirationDate as DateTime, the Salesforce implementation is a of the data type Date. |
| lot​Number | N/​A | N/​A | N/​A | Not supported |
| serial​Number | ​​Asset.​Serial​Number | String | 0​.1 | N/A |
| ​​device​​Name​.name | ​​Care​Registered​Device​.Name | String | 0.1 | While F​HI​R defines device.deviceName as a zero-to-many resource, the Salesforce implementation is zero-to-one​. |
| ​​device​​Name​.type | Lookup: ​​Care​Registered​Device​.Name​Type | Multi-Select Picklist | 0.M | While F​HI​R defines device.deviceName as a zero-to-many resource, the Salesforce implementation is zero-to-one​. |
| model​Number | ​​Asset​.Product​Code | String | 0​.1 | N/​A |
| part​Number | N/​A | N/​A | N/​A | Not supported |
| type | ​​Care​Registered​Device​.Device​TypeId | Lookup: Code​Set | 0.1 | While F​HI​R defines device.type as a codeable concept value, the Salesforce implementation is a code set. |
| specialization | N/​A | N/​A | N/​A | Not supported |
| version | N/​A | N/​A | N/​A | Not supported |
| property | N/​A | N/​A | N/​A | Not supported |
| patient | ​​Care​Registered​Device​​.PatientId | Lookup: Account | 0.1 | N/A |
| owner | ​​Asset.​Asset​Serviced​By | Lookup: Account | 0.1 | N/A |
| contact | ​​Care​Registered​Device​.Support​Contact​Detail | String | 0​.1 | While F​HI​R defines device.contact as a contact point value, the Salesforce implementation is a string. |
| location | N/​A | N/​A | N/​A | N/​A |
| url | ​​Asset.​Product​2Id​.Display​Url | URL | 0​.1 | N/​A |
| account | N/​A | N/​A | N/​A | Not supported |
| note​. | Author​Note | Object | 0​.M | The notes for a device are represented as AuthorNote records that reference the CareRegisteredDevice record using their ​​​AuthorNote​.​Parent​RecordId field​. |
| safety | ​​Care​Registered​Device​​.​Safety​Information | String | 0​.1 | While F​HI​R defines device.safety as a codeable concept, the Salesforce implementation is a string field. |
| parent | ​​Asset.​ParentId | Lookup Asset | 0​.1 | N/A |