schema_version: "1"
id: 36884a46971bb8eabdfcb257cfa28e0ddde1335db43ae6567e343e87692226d5
title: Troubleshooting Errors After Enabling Omnistudio Metadata
collection: admin
version: current
locale: en-us
portal_url: https://docs.salesforce.com/admin/current/en-us/xcloud/264-0-0/os_metadata_setting_troubleshooting.md
canonical_url: https://help.salesforce.com/s/articleView?id=xcloud.os_metadata_setting_troubleshooting.htm&release=264.0.0&type=5
source_site: help.salesforce.com
content_type: documentation
content_hash: 686c30f466443af9c439136f400b6f2d52b98eb77530f17d75439700ca38d607
description: If you see an error after enabling the Omnistudio Metadata setting, check for invalid names for components, Omnistudio Data Mapper version numbers, and populated configuration tables.
products:
  - Omnistudio
release: "264"
---
# Troubleshooting Errors After Enabling Omnistudio Metadata

If you see an error after enabling the Omnistudio Metadata setting, check for invalid names for components, Omnistudio Data Mapper version numbers, and populated configuration tables.

## Invalid Component Names

For successful migration, the names, types, and subtypes of all Omnistudio components must not have underscores, spaces, or special characters. 

- Omniscripts (OmniProcess object)
- Flexcards (OmniUiCard object)
- Data Mappers (OmniDataTransform object)
- Integration Procedures (OmniProcess object)

## Data Mapper Version Numbers

Data Mappers don't have version numbers. Open the Data Mappers and ensure they don't have a version number ("1"). If they don't, they aren’t versioned. You can run the following anonymous Apex in the Developer Console to correct this issue.

```
List<OmniDataTransform> allDrsToUpdate = new List<OmniDataTransform>();
for (OmniDataTransform om : [ Select Name, VersionNumber from OmniDataTransform WHERE UniqueName = null ]) {
if (om.VersionNumber == null) {
om.VersionNumber = 1;
}
allDrsToUpdate.add(om);
}
update allDrsToUpdate;
```

## Populated Config Tables

To check whether the configuration tables are populated, run a SOQL query in the Developer Console on these objects:

- OmniUiCardConfig
- OmniScriptConfig
- OmniIntegrationProcConfig
- OmniDataTransformConfig

Any existing records in these objects can prevent the setting from being enabled. Log in to the Developer Console and run a Select query to find any records on the objects.

- 1. Back up all Omnistudio components (OmniProcess, OmniDataTransform, OmniUiCard) by exporting all the records. For example, in the Omniscripts tab, select **Type** and click **Export**.
    2. After the backup is complete, manually delete all records returned by the SOQL queries for the respective configuration objects.

You can use the backups later to restore standard Omnistudio components if they were removed during the configuration table cleanup process. This scenario is rare.

## Deactivate Omniscripts and Flexcards

Deactivate Flexcards and Omniscripts, and then enable the Omnistudio Metadata setting.